Showing posts with label 3 NYS Multiple Dwelling Law. Show all posts
Showing posts with label 3 NYS Multiple Dwelling Law. Show all posts

APARTMENT

That part of a multiple dwelling consisting of one or more rooms containing at least one bathroom and arranged to be occupied by the members of a family, which room or rooms are separated and set apart from all other rooms within a multiple dwelling. ...more

BOARDER

(ROOMER, LODGER) An individual living within a household who pays a consideration for such residence and does not occupy such space as an incident of employment therein. ...more

CLASS A MULTIPLE DWELLING

A multiple dwelling which is occupied, as a rule, for permanent residence purposes. This class shall include tenements, flat houses, maisonette apartments, apartment houses, apartment hotels, bachelor apartments, studio apartments, duplex apartments, kitchenette apartments, garden-type maisonette dwelling projects, and all other multiple dwellings except Class B multiple dwellings.

See the List of Multiple Dwelling Classifications ...more

CLASS B MULTIPLE DWELLING

A multiple dwelling which is occupied, as a rule transiently, as the more or less temporary abode of individuals or families who are lodged with or without meals. This class shall include hotels, lodging houses, rooming houses, boarding houses, boarding schools, furnished room houses, lodgings, club houses, college and school dormitories and dwellings designed as private dwellings but occupied by one or two families with five or more transient boarders, roomers or lodgers in one household.

See the List of Multiple Dwelling Classifications ...more

CONVERTED DWELLING

A dwelling which

(a) was erected before 4/18/1929, to be occupied by one or two families living independently of each other and subsequently occupied as a multiple dwelling, or

(b) is three stories or less in height erected after 4/18/1929, to be occupied by one or two families living independently of each other and subsequently occupied by not more than three families in all, with a maximum occupancy of two families on each floor in a two STORY building and one family on each floor in a three STORY building, in compliance with the provisions of article six of the MDL, including section 170-a of said article. A converted dwelling occupied as a class A multiple dwelling is a class A converted dwelling; every other converted dwelling is a class B converted dwelling.

See the List of Multiple Dwelling Classifications


...more

DINING BAY

A "dining bay," "dining recess" or "dinette" is a recess used for dining purposes off a living room, foyer or kitchen. ...more

FAMILY

A single individual; or two or more individuals related by blood or marriage or who are parties to a domestic partnership, and living together and maintaining a common household, with not more than four BOARDERS, ROOMERS, or LODGERS; or a group of not more than four individuals, not necessarily related by blood, marriage or because they are parties to a domestic partnership, and maintaining a common household. (See also Zoning Definition of FAMILY)
...more

FIRE-ESCAPE

A FIRE-ESCAPE is a combination of outside balconies and stairs providing an unobstructed means of egress from rooms or spaces in a building. ...more

FIREPROOF MULTIPLE DWELLING

A "fireproof multiple dwelling" is one in which the walls and other structural members are of incombustible materials or assemblies meeting all of the requirements of the building code and with standard fire-resistive ratings of not less than one of the following sets of requirements:

a. For any multiple dwelling more than one hundred feet in height:

-4 hours for fire walls, party walls, piers, columns, interior structural members which carry walls, girders carrying columns, and for exterior walls other than panel walls.

-3 hours for other girders, fire partitions, floors including their beams and girders, beams, roofs, floor fillings, and stairway enclosures.

-2 hours for exterior panel walls.

b. For any multiple dwelling one hundred feet or less in height:

-4 hours for fire walls, party walls, piers, columns, interior structural members which carry walls, girders carrying columns.

-3 hours for exterior walls other than panel walls

-2 hours for panel walls, protection of interior columns

-1-1/2 hours for roofs and for floors and beams; provided, however, that for a multiple dwelling three stories or less in height, the requirement for all floors and the roof shall be 1 hour.
...more

FIRE-RETARDED

The term FIRE-RETARDED, as applied to a part or parts of a building, means such part or parts are either covered with metal lath plastered with two or more coats of mortar or otherwise protected against fire in a manner approved by the department with materials of standard fire-resistive ratings of at least one hour. Fireproofing shall always be accepted as meeting any requirement for fire-retarding. ...more

FIRE-STOPPING

FIRE-STOPPING means the closing of all concealed draft openings to form an effectual fire barrier at floors, ceilings and roofs with brick, concrete, gypsum, asbestos, mineral wool, rock wool, metal lath with cement or gypsum plaster, or other approved incombustible materials. ...more

FIRE-TOWER

A FIRE-TOWER is a fireproof stair, enclosed in fireproof walls, without access to the building from which it affords egress other than by a fireproof self-closing door opening on a communicating balcony or other outside platform at each floor level. ...more

FOYER

A space within an Apartment or dwelling unit in a multiple dwelling used as an entrance hall from the public hall, which is not a living room when its floor area does not exceed either: (a) ten percent of the total floor area of the dwelling unit; or (b) twenty percent of such floor area, if every living room is at least twenty percent larger than the required minimum room size. ...more

FRAME DWELLING

A dwelling of which the exterior walls or any structural parts of such walls are of wood. A dwelling which would not otherwise be a frame dwelling shall not be deemed a frame dwelling by reason of the existence on such dwelling of frame oriel, bay or dormer windows, frame porches not more than one STORY in height, or frame extensions not more than one STORY in height and fifty-nine square feet in area if such windows, porches or extensions were erected prior to 4/13/1940. ...more

FURNISHED ROOM HOUSE

Is a multiple dwelling, other than a hotel, having less than thirty sleeping rooms and in which persons either individually or as families are housed for hire or otherwise with or without meals. Synonomous with ROOMING HOUSE. ...more

GARDEN-TYPE MAISONETTE DWELLING PROJECT

A series of attached, DETACHED or semi-detached DWELLING UNITS which are provided as a group collectively with all essential services such as, but not limited to, water supply and house sewers, and which units are located on a site or plot not less than 20,000 square feet in area under common ownership and erected under plans filed with the department on or after 4/18/1954, and which units together and in their aggregate are arranged or designed to provide three or more apartments. ...more

HEREAFTER ERECTED CLASS A (HAEA)

Originally erected as a MULTIPLE DWELLING in accordance with the laws in effect after January 1, 1929, whether old code (pre-1968) or new code (post-1968). This includes all newly constructed multiple dwellings (3 dwelling units (DUs) or more).

• Also included are buildings originally erected as other than HAEA, subsequently altered under the old code to comply with NYS Multiple Dwelling Law (MDL) Article 3 and Article 4 or 5

• Also included are buildings originally erected as other than HAEA, subsequently altered under the new code to comply with all new code requirements for J-2.


See the List of Multiple Dwelling Classifications ...more

HEREAFTER ERECTED CLASS B (HAEB)

Originally erected as a MULTIPLE DWELLING in accordance with the laws in effect after January 1, 1929, whether old code (pre-1968) or new code (post-1968). This includes all newly constructed multiple dwellings (3 dwelling units (DUs) or more).

• Also included are buildings originally erected as other than HAEB, subsequently altered under the old code to comply with NYS Multiple Dwelling Law (MDL) Article 3 and Article 4 or 5

• Also included are buildings originally erected as other than HAEB, subsequently altered under the new code to comply with all new code requirements for J-2.


See the List of Multiple Dwelling Classifications ...more

HOTEL

An inn having thirty or more sleeping rooms. ...more

IMD

IMD stands for Interim Multiple Dwelling.

An Interim Multiple Dwelling is a building which:

1. Possesses no residential certificate of occupancy pursuant to §301 of the Multiple Dwelling Law;

2. Was used in the past for manufacturing, commercial or warehousing purposes

3. Had three or more residential tenants living in separate apartments in the building in the 20-month period between April 1, 1980, and December 1, 1981 (the "statutory window period").

See the NYC Loft Board Website and Permitspace Entry regarding IMD's for more information. Also, refer to Article 7-C of the Multiple Dwelling Law. ...more